4x Digital Input Phidget
Add 4 digital inputs to your VINT Hub. These inputs have a shorter trigger time than a VINT port in Digital Input mode.
If you need isolation, compatibility with higher voltages, or more digital inputs per VINT port, have a look at the "Other Digital Inputs" tab for more options.
If you plan on counting pulses on a high-frequency signal (faster than 500 Hz) or to measure pulses shorter than 2ms in length, you'll want to use one of our specialized frequency counter Phidgets instead.
Board Properties |
|
Controlled By |
VINT |
Electrical Properties |
|
Current Consumption Min |
27 μA |
Current Consumption Max |
* 2 mA |
Digital Inputs |
|
Number of Digital Inputs |
4 |
Digital Input Voltage Max |
5 V DC |
Low Voltage Max (True) |
1.5 V DC |
High Voltage Min (False) |
3.5 V DC |
Low Voltage Trigger Length Min |
2 ms |
High Voltage Trigger Length Min |
2 ms |
Physical Properties |
|
Recommended Wire Size |
16-26 AWG |
Operating Temperature Min |
-40 °C |
Operating Temperature Max |
85 °C |
* Note: Current consumption is equal to 27µA plus 500µA for each digital input that is grounded.