1139_0 Differential Gas Pressure Sensor 100 kPa, 1139
This differential air pressure sensor plugs into an Analog Input or VINT Hub port and measures pressure from 0 kPa to 100 kPa.
The 1139 Differential Pressure Sensor is a dual ported air pressure sensor that measures the pressure difference between the two ports. It can measure pressure from 0 kPa to 100 kPa.
Sensor Properties
Sensor Type |
Gas Pressure (Differential) |
Sensor Output Type |
Ratiometric |
Pressure Differential Min |
0 Pa |
Pressure Differential Max |
100 kPa |
Case Pressure Max |
400 kPa |
Pressure Resolution |
111 Pa |
Measurement Error Max |
± 2.5 % |
Warm-up Time |
20 ms |
Response Time Max |
1 ms |
Electrical Properties
Supply Voltage Min |
4.8 V DC |
Supply Voltage Max |
5.3 V DC |
Current Consumption Max |
10 mA |
Output Impedance |
1 kΩ |
Output Voltage Min |
250 mV DC |
Output Voltage Max |
4.8 V DC |
Physical Properties
Operating Temperature Min |
-40 °C |
Operating Temperature Max |
125 °C |
Recommended Tubing Size |
3⁄32″ |
This sensor is designed to measure the pressure of clean, non-condensing air. Contact with moist air (i.e, human breath), dusty air, or other gases can damage the sensor. |