VCP1001_0

(±40V) Voltage Input Phidget

£30.60 £25.50

This Phidget measures voltage potentials of up to ±40V.

It connects to a VINT port and is isolated for increased reliability.

Or

When a 0-5V voltage input isn't enough, this Phidget can be used to measure voltages up to ±40V. You can select the voltage range (±5V, ±15V or ±40V) in software; a smaller range results in higher precision.

This Phidget also has an automatic mode that continuously adjusts the range based on present voltage measurements, so you'll always have the most accurate measurement possible.

The VCP1001 connects to a port on a VINT Hub.

 

Sensor Properties

Sensor Type

Voltage (DC)

Board Properties

Controlled By

VINT

Voltage Sensor

Withstand Voltage Max

± 50 V DC

Number of Voltage Inputs

1

Sensor Input Impedance

1 MΩ

Voltage Difference Max

± 40 V DC

Sampling Interval Min

40 ms/sample

Sampling Interval Max 

60 s/sample

±5V Range

Voltage Resolution

200 μV DC

Voltage Offset Max

5 mV DC

Measurement Error Max

0.2 %

Voltage Noise

3 mV DC

±15V Range

Voltage Resolution

500 μV DC

Voltage Offset Max

15 mV DC

Measurement Error Max

0.2 %

Voltage Noise

10 mV DC

±40V Range

Voltage Resolution

1.2 mV DC

Voltage Offset Max

40 mV DC

Measurement Error Max

0.2 %

Voltage Noise

25 mV DC

Electrical Properties

Current Consumption Max

11 mA

Physical Properties

Recommended Wire Size

16 - 26 AWG

Operating Temperature Min

-40 °C

Operating Temperature Max

85 °C